Advantage:
1).NU(IPC) SERIES INSULATION PIERCING CONNECTOR had passed 6KV test under water for 1 Min.
2).Designed for all weather applications and easy to install.
3).Its self-seam frame is wet proof, water proof, and anti-corrosive, which can prolong the using life of insulated lead and connector.
Instructions:
Purpose of Insulation piercing connectors (NU) is to connect main and one, two tap conductor s ' of section, how is written on NU body. Type without letter B serves to connect isolated conductors, with letter B bare conductors.NU for one tap conductor is equipped with cable termination cap PCEC16/120, for two output wires-no cap.
1).Adjust the connector nut to suitable location.
2).Put the branch wire into the cap sheath fully.
3).Insert the main wire, if there are two lays of insulated lay in the main cable, should strip a certain length of the first insulated lay from inserted end.
4).Turn the nut by hand, and fix the connector in suitable location.
5).Screw the nut with the sleeve spanner.
6).Screw the nut continually until the top part is cracked and dropped down.
Item No. | Main wire section | Branch wire section | Bolt |
NU-1 | 10-95 | 1.5-10 | 1 |
NU-2 | 16-95 | 4-35 | 1 |
NU-3 | 50-150 | 6-35 | 1 |
NU-4 | 16-95 | 16-95 | 1 |
NU-5 | 35-150 | 35-150 | 1 |
JBC SERIES INSULATION PIERCING CONNECTOR
Features:
1).It is featuring a unique insulation technique.
2).Connections can be made live in minutes and suitable for aluminum or Copper, the body materials are UV-resistant.
Advantages:
1).Designed for all weather applications and easy to install.
2).Special connecting tablet is adopted in our insulation piercing connector, which is applicable to joint of Cu(Al) and Cu(Al) or Cu and Al.
3).The self-seam frame of JBC Series Insulation Piercing Connector is wet proof, water proof, and anti-corrosive, which can prolong the using life of insulated lead and connector.
4).Saving investments: first, less installation space needed; second, saving cost of bridge and civil engineering; third, it does not require terminal boxes, distribution boxes when building.
Instructions:
Full range of ABC Insulation Piercing Connectors used to tap off low voltage XLPE insulated Aerial Bundled Cable (ABC).
1).Adjust the connector nut to suitable location.
2).Put the branch wire into the cap sheath fully.
3).Insert the main wire, if there are two lays of insulated lay in the main cable, should strip a certain length of the first insulated lay from inserted end.
4).Turn the nut by hand, and fix the connector in suitable location.
5).Screw the nut with the sleeve spanner.
6).Screw the nut continually until the top part is cracked and dropped down.
Item No. | Main wire section | Branch wire section | Bolt |
JBC-0 | 25-70 | 6-35 | 1 |
JBC-1 | 35-70 | 6-35 | 1 |
JBC-2 | 35-150 | 35-150 | 1 |
JBC-3 | 50-240 | 50-150 | 2 |
CPB SERIES INSULATION PIERCING CONNECTOR
Features:
1)It is featuring a unique insulation technique.
2)Connections can be made live in minutes and suitable for aluminum or Copper, the body materials are UV-resistant.
Advantage:
1).CPB Series Insulation Piercing Connector Pass 6kv test under water for 1min.
2).As the branch anywhere in the cable.
3).Simple installation, small contact resistance and low temperature rise of the clamp.
4).Its self-seam frame is wet proof, water proof, and anti-corrosive, which can prolong the using life of insulated lead and connector.
Item No. | Main wire section | Branch wire section | Bolt |
CPB25-25 | 10-25 | 10-25 | 1 |
CPB25-70 | 16-70 | 4-25 | 1 |
CPB70-70 | 16-70 | 16-70 | 1 |
CPB95-95 | 16-95 | 16-95 | 1 |
CPC SERIES INSULATION PIERCING CONNECTOR
Application:
The CPC insulation piercing connectors are applicable for all types of LV-ABC.
Features:
1. Had passed 6KV test under water for 1 Min.
2. Simple installation, small contact resistance and low temperature rise of the clamp. The body materials are UV-resistant.
3. Its self-seam frame is wet proof, water proof, and anti-corr osive, which can prolong the using life of insulated lead and connector.
4. Standard: EN 50483-4, NFC 33-020, NFC 33-004
Item No. | Main wire section | Branch wire section |
CPC-1 | Al 25-95 | Al 2.5-95 |
CPC-2 | 35 | 2.5-35 |
CPC-3 | 70 | 2X(6-35) |
TTD Insulation Piercing Connectors
2)Connections can be made live in minutes and suitable for aluminum or Copper, the body materials are UV-resistant.
Advantages:
1).Designed for all weather applications and easy to install.
2).Special connecting tablet is adopted in our insulation piercing connector, which is applicable to joint of Cu(Al) and Cu(Al) or Cu and Al.
3).Its self-seam frame is wet proof, water proof, and anti-corrosive, which can prolong the using life of insulated lead and connector.
Instructions:
TTD series insulation piercing connector is not only used to connect the (or separate) the self-supporting insulated wire, but also used to separate lighting circuit.
1).Adjust the connector nut to suitable location.
2).Put the branch wire into the cap sheath fully.
3).Insert the main wire, if there are two lays of insulated lay in the main cable, should strip a certain length of the first insulated lay from inserted end.
4).Turn the nut by hand, and fix the connector in suitable location.
5).Screw the nut with the sleeve spanner.
6).Screw the nut continually until the top part is cracked and dropped down
Item No. | Main wire section | Branch wire section | Bolt |
TTD-82F | AL25-95 | AL 2*(2.5-35) | 1 |
TTD-151F | AL25-95 | AL2.5-35 | 1 |
TTD-201F | AL35-95 | AL25-95 | 1 |
TTD-281F | AL120-185 | AL10-25 | 1 |
TTD-301F | AL35-95 | AL25-95 | 2 |
TTD-401F | AL50-185 | AL50-150 | 2 |
TTD-451F | AL120-185 | AL70-185 | 2 |
2D55 Overhead Fittings
Application:
1. The 2D55 insulation piercing connectors are applicable for all types of LV-ABC.
2. Had passed 6KV test under water for 1 Min.
Feature:
1. Simple installation, small contact resistance and low temperaturerise of the clamp. The body materials are UV-resistant.
2. Its self-seam frame is wet proof, water proof, and anti-corrosive,which can prolong the using life of insulated lead and connector.
3. Standard: EN 50483-4, NFC 33-020, NFC 33-004
Item No. | Main wire section | Branch wire section |
2D55 | 35-95 | 2×2.5-35 |
Eletrical Ageing Test Report.pdf